Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
ALPLINK01_062 Alpha V6.1 - 6.2-1H3 Linker ECO Summary
Copyright (c) Digital Equipment Corporation 1994, 1998. All rights reserved.
OP/SYS: DIGITAL OpenVMS Alpha
COMPONENT: LINK
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: ALPLINK01_062
ECO Kits Superseded by This ECO Kit: AXPLINK02_061
AXPLINK01_061 (CSCPAT_2069 V1.0)
ECO Kit Size: Saveset A - 162 Blocks
Saveset B - 576 Blocks
Saveset C - 576 Blocks
Cover Letter - 6 Blocks
Total of 4 files - 1320 Blocks
Kit Applies To: OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2
V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3
System Reboot Necessary: No
Cluster Reboot Necessary: Yes
ECO KIT SUMMARY:
An ECO (patch) kit exists for LINK.EXE on OpenVMS Alpha V6.1 through
V6.2-1H3. This kit addresses the following problems:
Problems Fixed in ALPLINK01_062 for OpenVMS Alpha V6.1, V6.1-1H1,
V6.1-1H2, V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3:
o When linking a large image, an access violation can occur if
an image section reaches 65536 512-byte blocks in size.
Problems Fixed in AXPLINK02_061 for OpenVMS Alpha V6.1:
o Linking an ADA application with the ADA Compilation System
("ACS") takes an unacceptably long time. The fix contained
in this kit will be of benefit only if the V3.2 DEC ADA Compiler
is installed on the system. However, this is not a problem with
the ADA Compiler.
Problems Fixed in AXPLINK01_061 for OpenVMS Alpha V6.1:
o Modifications have been made to the linker to prevent removal
of relocation or fixup information from the deferred list when
the linker is in "debug" context.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
the OPENVMS database. To view these articles, open the appropriate
product database and perform a query using either of the following
search strings: 'ALPLINK01_062', 'ALPLINK' or 'AXPLINK'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, if you have other nodes in your VMScluster, they should be
rebooted or you should install this kit on each system in order to
make use of the new image(s).
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| LINK.EXE | 16329734 | A11-34 | 19-DEC-1995 |
| | | 00:21:07.71 |
+----------------------------+----------+-----------------+--------------+
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| LINK.EXE | F4D8ED77 | A11-35 | 13-DEC-1995 |
| | | 03:00:04.54 |
+----------------------------+----------+-----------------+--------------+
|