Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
CSCPAT_0245 MTDISMOUNT.EXE ECO Summary
Copyright (c) Digital Equipment Corporation 1994, 1995. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENT: System
SOURCE: Digital Customer Support Center
ECO INFORMATION:
CSCPAT Kit: CSCPAT_0245 V1.9 (CSCPAT_0245019)
CSCPAT Kit Size: 72 Blocks
Engineering Cross Reference: Not Applicable
Kit Applies To: OpenVMS VAX V5.0, V5.0-1, V5.0-2,
V5.1, V5.1-B, V5.1-1, V5.1-2,
V5.2, V5.2-1, V5.3, V5.3-1, V5.3-2,
V5.4, V5.4-1, V5.4-2, V5.4-3,
V5.5, V5.5-1, V5.5-2, V6.0, V6.1, V6.2
System Reboot Necessary: No
NOTE: CSCPAT_0245 has been revised and now only contains the following
remedial program:
CSCPAT_0245_USE_WITH_CAUTION_MTDISMOUNT.EXE
Other images contained in past revisions of CSCPAT_0245
are now contained in CSCPAT_0253. For more information,
refer to the following article in the ECO-SUMMARY database:
*OpenVMS] CSCPAT_0253 I/O Routines ECO Summary
ECO KIT SUMMARY:
An ECO kit exists for MTDISMOUNT.EXE on OpenVMS VAX V5.0 through V6.2.
This kit addresses the following problem:
o A device mounted foreign may become inaccessible after a
dismount or may appear to be allocated to a nonexistent
process. The system must be rebooted to regain access to the
device. CSCPAT_0253 corrects this problem in most cases.
However, the problem may still occur on some systems after this
patch kit has been installed.
This kit provides a program called
'CSCPAT_0245_USE_WITH_CAUTION_MTDISMOUNT.EXE'
that will allow the user to deallocate a device allocated
to a non-existent process.
************************************************************
* *
* CAUTION *
* *
* This image needs to be run from an account with CMKRNL *
* and WORLD privilege and should be used with extreme *
* caution. A system crash and reboot may occur if *
* instructions are not followed carefully. *
* *
************************************************************
To run the image, the following steps must be performed:
1. Ensure that the device is allocated to a process that no longer
exists on the system by using the $SHOW DEVICE/FULL and $SHOW
PROCESS commands. If the device is not allocated or it is
allocated to an existing process, the program will exit with
the error message:
%SYSTEM-F-DEVNOTDISM, device not dismounted
2. Run the CSCPAT_0245_USE_WITH_CAUTION_MTDISMOUNT.EXE image using
the following command:
$ RUN SYS$MANAGER:CSCPAT_0245_USE_WITH_CAUTION_MTDISMOUNT
The program outputs the following message and prompts for the device
name to be released:
----------------------------------------------------------
MTDISMOUNT V02.02
This program is provided by the DIGITAL Customer Support Center
in conjunction with CSCPAT_0245. It must be used ONLY for its
intended purpose - to recover from the symptom described in
file SYS$HELP:CSCPAT_024501*.RELEASE_NOTES where a tape device
becomes allocated to a nonexistent process. The user of this
program must have CMKRNL and WORLD privilege. To obtain
additional information, contact the Customer Support Center by
calling (800)345-9000.
Device Name:
--------------------------------------------------------
3. Verify that the device is no longer allocated using the DCL
command 'SHOW DEVICE/FULL'. The device should no longer be
allocated if the steps above were followed correctly.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
the OPENVMS database. To view these articles, open the appropriate
product database and perform a query using the search string
'CSCPAT_0245'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services (AES)
Service Tool. If you are not familiar with how to request kits
electronically, open the DIA, WIS or DSNLINK database and review the
article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
The system/cluster does not need to be rebooted after this kit is
installed.
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| CSCPAT_0245_USE_WITH_CAUTION_MTDISMOUNT.EXE |
| |%XD509E653| CSC/CS MTDMT V2 | 5-NOV-1991 |
| | | 14:38:52.54 |
+----------------------------+----------+-----------------+--------------+
| CSCPAT_0245_USE_WITH_CAUTION_MTDISMOUNT.EXE |
| |%XD508E05B| CSC/CS MTDMT V2 | 27-OCT-1993 |
| | | 07:06:28.58 |
+----------------------------+----------+-----------------+--------------+
|