Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
CSCPAT_2022 Alpha V1.5 F11BXQP.EXE ECO Summary
Copyright (c) Digital Equipment Corporation 1994. All rights reserved.
Modification Date: 09-NOV-2001
Modification Type: Note added regarding this kit is no longer
available through SSB.
OP/SYS: OpenVMS Alpha
COMPONENT: File System
F11BXQP.EXE
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
CSCPAT Kit: CSCPAT_2022 V1.0 (CSCPAT_2022010)
CSCPAT Kit Size: 720 Blocks
Engineering Cross Reference: AXPF11X01_015
Kit Applies To: OpenVMS Alpha V1.5
System Reboot Necessary: Yes
***********************************************************************
* NOTE *
* *
* THIS KIT IS NO LONGER AVAILABLE THROUGH SSB. *
* *
***********************************************************************
ECO KIT SUMMARY:
An ECO kit exists for F11BXQP.EXE on OpenVMS Alpha V1.5. This
kit addresses the following problem:
o When the QUOTA.SYS file is extended from an AXP node in a
VMScluster, problems occur. The following symptoms have
been observed:
1. From all other nodes in the VMScluster, performing
ANALYZE/DISK for the disk in question will result in the
following error:
%ANALDISK-W-READQUOTA, error reading QUOTA.SYS, VBN <x>
-SYSTEM-W-ENDOFFILE, end of file.
2. From all other nodes in the VMScluster, when the command
"SYSMAN> DISKQUOTA SHOW *" is issued, only the information
for users in the pre-extended QUOTA.SYS will be displayed.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist
in the OPENVMS database. To view these articles, open the
appropriate product database and perform a query using either of
the following search strings: 'CSCPAT_2022' or 'AXPF11X'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
In order for the corrections in this kit to take effect, the system
must be rebooted. If the system is a member of a VMScluster, the
entire cluster should be rebooted.
==========================================================================
| Table of Kit Image Information |
+------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+------------------------+----------+-----------------+--------------+
| F11BXQP.EXE | 2C19E67A | X-3 | 8-SEP-1993 |
| | | 15:19:55.42 |
+------------------------+----------+-----------------+--------------+
|