Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
CSCPAT_1047 MONITOR Utility ECO Summary
Copyright (c) Digital Equipment Corporation 1994. All rights reserved.
Modification Date: 14-NOV-2001
Modification Type: Note added regarding this kit is no longer
available through SSB.
OP/SYS: OpenVMS VAX
COMPONENT: MONITOR Utility - SPISHR.EXE
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
CSCPAT Kit: CSCPAT_1047 V1.0 (CSCPAT_1047010)
CSCPAT Kit Size: 216 Blocks
Engineering Cross Reference: MONTOR$S01_050, MONTOR$S01_052
MONTOR$S01_053, MONTOR$S01_054
Kit Applies To: OpenVMS VAX V5.0, V5.0-1, V5.0-2, V5.1, V5.1-1,
V5.1-2, V5.2, V5.2-1, V5.3, V5.3-1,
V5.3-2, V5.4, V5.4-1, V5.4-2
System Reboot Necessary: Yes
***********************************************************************
* NOTE *
* *
* THIS KIT IS NO LONGER AVAILABLE THROUGH SSB. *
* *
***********************************************************************
ECO KIT SUMMARY:
An ECO kit exists for MONITOR Utility on OpenVMS VAX V5.0
through V5.4-2. This kit addresses the following problems:
o Unauthorized privileges may be given to authorized users of a
system under certain conditions using the MONITOR Utility.
Should a system be compromised through unauthorized access, there
is a risk of potential damage to the system environment.
NOTE: This problem will NOT permit unauthorized access entry,
as individuals attempting to gain unauthorized access will
continue to be denied through the standard VMS security
mechanisms.
This problem is fixed in OpenVMS VAX V5.4-3.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
the OPENVMS database. To view these articles, open the appropriate
product database and perform a query using the search string
'CSCPAT_1047'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
A system reboot is highly recommended following the installation of
this kit.
NOTE: Should you upgrade to one of the VMS releases affected, this
kit must be re-applied, re-using this kit to obtain the
appropriate image for your new VMS version.
For VAXcluster installations, the SPISHR.EXE needs its image replaced
on all members in the cluster, thus the following command needs to be
invoked on all members at the completion of this patch kit
installation.
$ INSTALL
INSTALL> REPLACE SYS$SHARE:SPISHR.EXE
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| SPISHR.EXE |%X02E2229F| X-7 | 8-APR-1988 |
| | | 05:28:43.30 |
+----------------------------+----------+-----------------+--------------+
| SPISHR.EXE |%XA2C788E2| X-7 | 10-MAY-1989 |
| | | 18:07:17.18 |
+----------------------------+----------+-----------------+--------------+
| SPISHR.EXE |%XA2C788E2| X-7 | 12-OCT-1989 |
| | | 00:47:31.56 |
+----------------------------+----------+-----------------+--------------+
| SPISHR.EXE |%XE1EE252D| X-7 | 19-JUN-1990 |
| | | 05:22:00.07 |
+----------------------------+----------+-----------------+--------------+
|