Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
VMS62TO71_PCSI-V0200 VAX V6.2 and V7.1 PCSI ECO Summary
Copyright (c) Compaq Computer Corporation 1998, 2000. All rights reserved.
Modification Date: 03-MAY-2000
Modification Type: Updated Kit: Supersedes VMS62TO71_PCSI-V0100
OP/SYS: OpenVMS VAX
COMPONENT: PCSI
PCSI$MAIL.EXE
PCSI$SHR.EXE
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS62TO71_PCSI-V0200
DEC-VAXVMS-VMS62TO71_PCSI-V0200--4.PCSI
ECO Kits Superseded by This ECO Kit: VMS62TO71_PCSI-V0100
ECO Kit Approximate Size: 1968 Blocks
Kit Applies To: OpenVMS VAX V6.2, V7.1
System/Cluster Reboot Necessary: No
Rolling Re-boot Supported: Not Applicable
Installation Rating: INSTALL_2
2 - To be installed on all systems running
the listed version(s) of OpenVMS and
using the following feature(s):
New PRODUCT command functionality
Layered product installation instructions
that require this remedial kit to be
installed as a prerequisite
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for PCSI on VAX V6.2 through V7.1.
New Functionality Included in VMS62TO71_PCSI-V0200:
o This remedial kit updates the POLYCENTER Software Installation
utility of OpenVMS, including associated command procedures
and help text. After installation, the POLYCENTER Software
Installation facility will be functionally equivalent to that
provided by OpenVMS V7.2. Changes include new PRODUCT
commands and qualifiers, improved display of output from
PRODUCT SHOW commands, features useful for product developers,
and several corrections for problems that have been fixed
since OpenVMS V7.2 was released.
After installaton of this remedial kit your system will use
the new features provided by this version of the POLYCENTER
Software Installation utility. If a layered product is
installed that makes use of this new functionality, then it
may not be possible to revert back to an older version of the
utility. This restriction occurs because there may be records
in the software product database that the older version of the
utility will not be able to interpret. This scenario may
occur after an OpenVMS upgrade to a version of OpenVMS prior
to V7.1-2. For example, this situation occurs if you:
1. Install this remedial kit on VMS V6.2 or V7.1
2. Install DWMOTIF V1.2-5
3. Upgrade to (or re-install) VMS V6.2 or V7.1
The upgrade to any of the versions listed in #3 above may fail
(or other PRODUCT command operations on the product database
may fail) with one of the following errors:
%SYSTEM-F-ACCVIO, access violation, ...
or
%PCSI-E-UNSDOCENC, unsupported product document encoding version
To prevent these failures after installing this remedial kit
and the DWMOTIF product (as in the example above), do the
following:
1. Remove DWMOTIF using the command:
$ PRODUCT REMOVE DWMOTIF
2. Upgrade to (or re-install) VMS V6.2 or V7.1
3. Re-install this remedial kit
4. Re-install DWMOTIF
This workaround is not needed if you are upgrading to OpenVMS
VAX V7.2. These releases already include the new features
provided by this remedial kit to eliminate this issue.
Images Affected:
- [SYSEXE]PCSI$MAIN.EXE
- [SYSLIB]PCSI$SHR.EXE
New Functionality Included in VMS62TO71_PCSI-V0100:
o This remedial kit updates the POLYCENTER Software Installation
utility of OpenVMS, including associated command procedures
and help text. After installation, the POLYCENTER Software
Installation facility will be functionally equivalent to that
provided by OpenVMS V7.2. Changes include new PRODUCT
commands and qualifiers, improved display of output from
PRODUCT SHOW commands, features useful for product developers,
and problem corrections.
After installation of this remedial kit your system will use
the new features provided by this version of the POLYCENTER
Software Installation utility. If a layered product is
installed that makes use of this new functionality, then it
may not be possible to revert back to an older version of the
utility. This restriction occurs because there may be records
in the software product database that the older version of the
utility will not be able to interpret. This scenario may
occur after an OpenVMS upgrade to a version of OpenVMS prior
to V7.1-2. For example, this situation occurs if you:
1. Install this remedial kit on VMS V6.2 or V7.1
2. Install DWMOTIF V1.2-5
3. Upgrade to (or re-install) VMS V6.2 or V7.1
The upgrade to any of the versions listed in #3 above may fail
(or other PRODUCT command operations on the product database
may fail) with one of the following errors:
SYSTEM-F-ACCVIO, access violation, ...
or
%PCSI-E-UNSDOCENC, unsupported product document encoding version
To prevent these failures after installing this remedial kit
and the DWMOTIF product (in the example above), do the
following:
1. Remove DWMOTIF using the command:
$ PRODUCT REMOVE DWMOTIF
2. Upgrade to (or re-install) VMS V6.2 or V7.1
3. Re-install this remedial kit
4. Re-install DWMOTIF
This workaround is not needed if you are upgrading to OpenVMS
VAX V7.2 because these releases already include the functionality
provided by this remedial kit.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
the OPENVMS database. To view these articles, open the appropriate
product database and perform a query using either of the following
search strings: 'DEC-VAXVMS-VMS62TO71_PCSI-V0200.PCSI' or
'VMS62TO71_PCSI-V0200'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, all processes will need to log out and then back in to use
the new PRODUCT command qualifiers and keywords.
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| PCSI$MAIN.EXE |%XD94043FB| X11.1 | 14-MAR-2000 |
| | | 17:11:57.47 |
+----------------------------+----------+-----------------+--------------+
| PCSI$SHR.EXE |%XCE685A12| X11.1 | 14-MAR-2000 |
| | | 17:11:35.47 |
+----------------------------+----------+-----------------+--------------+
All trademarks are the property of their respective owners.
|