Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS72_PCSI-V0100 Alpha V7.2 PCSI ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
      
    Copyright (c) Compaq Computer Corporation 2000.  All rights reserved.
    
    Modification Date:  03-MAY-2000
    Modification Type:  New Kit
    
    OP/SYS:     OpenVMS Alpha
    
    COMPONENT:  PCSI
                  PCSI$MAIN.EXE
                  PCSI$SHR.EXE
    
    SOURCE:     Compaq Computer Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS72_PCSI-V0100
                        DEC-AXPVMS-VMS72_PCSI-V0100--4.PCSI
         ECO Kits Superseded by This ECO Kit:  None
         ECO Kit Approximate Size:  3600 Blocks
         Kit Applies To:  OpenVMS Alpha V7.2
         System/Cluster Reboot Necessary:  No
         Rolling Re-boot Supported:  Not Applicable
         Installation Rating:  INSTALL_1
                               1 - To be installed by all customers.
    
         Kit Dependencies:
    
           The following remedial kit(s) must be installed BEFORE
           installation of this kit:
    
             None
    
           In order to receive all the corrections listed in this
           kit, the following remedial kits should also be installed:
    
             None
    
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for PCSI on Alpha V7.2.  The new kit addresses
    the following problems:
    
      o  When installing FORTRAN and FORRTL products, the system hangs
         if both products are selected for installation at the same
         time.
    
         Images Affected:
           -  [SYSLIB]PCSI$SHR.EXE
           -  [SYSEXE]PCSI$MAIN.EXE
    
      o  An un-repairable PCSI database corruption is possible if the
         following PCSI steps are taken:
    
           1.  Install a FULL type product kit
    
           2.  Patch the FULL product with a PATCH type kit(s)
    
           3.  Install a PARTIAL type software product on top of the FULL
               kit
    
         then, two versions of the same FULL product are created and
         patches are not transferred from the FULL product to the
         PARTIAL product.  This would eventually lead to an
         un-repairable PCSI database corruption.
    
         Images Affected:
           -  [SYSEXE]PCSI$MAIN.EXE
           -  [SYSLIB]PCSI$SHR.EXE
    
      o  The following duplicate error messages are reported by the
         PCSI utility display during a product upgrade:
    
           %PCSI-E-INSVOLSPC, insufficient space on volume DISK$ALPCSI_SYS
            -PCSI-I-VOLSPC, 159261 required; 124344 available; -34917 net
           Terminating is strongly recommended.
           Do you want to terminate? [YES] no
    
           %PCSI-E-INSVOLSPC, insufficient space on volume DISK$ALPCSI_SYS
            -PCSI-I-VOLSPC, 159261 required; 124344 available; -34917 net
           Terminating is strongly recommended.
           Do you want to terminate? [YES] no
    
           Images Affected:
             -  [SYSLIB]PCSI$SHR.EXE
    
      o  The reinstallation of a PARTIAL kit causes an ACCVIO.  This
         occurs when certain data is passed from one instance of the
         PARTIAL product to another instance of the same product.
         After the transfer, pointers to the originating data
         structures are cleared.  These pointers will be needed later.
    
         When the PARTIAL kits are different, re-installation of
         PARTIAL kit will not clear pointers.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  An OpenVMS upgrade would generate an unexpected prompt to
         terminate the operation.
    
         Images Affected:
           -  [SYSLIB]PCSI$SHR.EXE
           -  [SYSEXE]PCSI$MAIN.EXE
    
      o  During the re-installation of a product that has a library
         module in its Product Description File (PDF), the PCSI
         utility terminates with an ACCVIO error.
    
         Images Affected:
           -  [SYSLIB]PCSI$SHR.EXE
           -  [SYSEXE]PCSI$MAIN.EXE
    
      o  Changed the behavior of file conflict resolution between a
         file from the kit being installed and a file with the same
         name that has already been installed.  Previously, when two
         files had the same generation number, the PCSI utility would
         retain the file already on the system disk.  Now when there is
         a tie, the file from the kit being installed replaces the file
         previously installed.
    
         Images Affected:
           -  [SYSLIB]PCSI$SHR.EXE
           -  [SYSEXE]PCSI$MAIN.EXE
    
      o  When a PRODUCT RECONFIGURE command is executed and the
         re-configured product has two or more patches applied to it,
         the PCSI utility incorrectly marks the patches as removed.
         This inconsistency can cause an ACCVIO on subsequent
         operations.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  When an OpenVMS partial kit is installed to upgrade the full
         version of OpenVMS, new files supplied by the partial kit that
         should replace the ones provided by the full OpenVMS version
         are ignored by the PCSI utility.
    
         Images Affected:
           -  [SYSLIB]PCSI$SHR.EXE
    
      o  The PCSI utility returns the %PCSI-F-ASSERTFAIL error
         message and aborts when upgrading the OpenVMS operating
         system with a partial kit.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  When a FULL product kit replaces a file provided by another
         product, or a PATCH product kit replaces a file provided by
         its parent product or another patch, use of the IMAGE LIBRARY
         option of the FILE statement in the PDF (Product Description
         File) must be used consistently.  For example, if one product
         provides a file and places it in SYS$LIBRARY:IMAGELIB.OLB, but
         another product replaces the file but does not specify that it
         should also be placed in image library, then the installation
         will fail with a %PCSI-E-PARUDF error message.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  Installing OpenVMS patch kits out of order results in a
         %SYSTEM-F-ACCVIO access violation.  The proper order, assuming
         OpenVMS is already loaded, is:
    
           1.  Install the latest patch first, then any additional
               patches in descending order, based upon Release Version,
               e.g., V5.1, V4.2, V3.4, etc.
    
           2.  Install the patch UPDATE V1.0, then UPDATE02 V1.0, and
               then re-install patch UPDATE V1.0.
    
          Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  Update the PCSI internal version to V7.2-108.  This version
         can be seen via a PRODUCT SHOW UTILITY command.
    
         Also Update the copyright notice.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  During installation, PCSI bases its required disk space
         calculation on deleting the old versions of images that are
         changed, thus freeing up disk space.  OpenVMS remedial kits
         do not delete the old images and therefore do not free up any
         disk space.  This caused the PCSI utility to under estimate
         the amount of free disk space required to install a product or
         patch kit.  If the disk space requirement is under estimated
         and there is insufficient free space, the following errors are
         reported:
    
           %PCSI-E-OPENOUT, ...
            -RMS-F-FUL, device full
           %PCSI-E-OPFAILED
            Terminating is strongly recommended
    
         The result is an incomplete installation of the files from the
         kit.   For an ECO to the operating system, there is risk that
         the system may be unusable.
    
         This change modifies the PCSI disk space calculation to take
         into account the fact that remedial kits do not delete old
         images.
    
         Images Affected:
           -  [SYSEXE]PCSI$MAIN.EXE
           -  [SYSLIB]PCSI$SHR.EXE
    
      o  An attempt to upgrade a product and also apply a patch (or
         ECO) kit to it in the same PRODUCT INSTALL opertion may fail
         with the following error:
    
           %PCSI-E-FAILCONF, ...
    
         Images Affected:
           -  [SYSEXE]PCSI$MAIN.EXE
           -  [SYSLIB]PCSI$SHR.EXE
    
      o  Installation of two or more patch kits that provide the same
         file, and also update IMAGELIB.OLB with the file, may cause
         the PCSI product database to be inconsistent if the patch kits
         are installed out of order.  Symptons include:
    
           +  Output from a PRODUCT SHOW OBJECT /FULL command shows
              that all versions of the file are in conflict with one
              another (i.e., no file in the set has a status of "OK").
    
           +  Output from a PRODUCT SHOW OBJECT /FULL command shows
              that the owner of the file is one product and the owner
              of the module in IMAGELIB.OLB is another product (or
              patch).
    
         Images Affected:
           -  [SYSEXE]PCSI$MAIN.EXE
           -  [SYSLIB]PCSI$SHR.EXE
    
      o  Installation of the DWMOTIF V1.2-5 product from a sequential
         kit (that is, a .PCSI file) appears to hang in the initial
         phase of the process.  After a delay (typically of 1 to 5
         minutes), the configuration dialog continues.  The delay
         occurs immediately after the PCSI utility issues the message:
    
           "Configuration phase starting ..."
    
         Images Affected:
           -  [SYSLIB]PCSI$SHR.EXE
           -  [SYSLIB]PCSI$SHR.EXE
    
      o  When a number of patch kits are installed in a descending
         version sequence, and they contain files with IMAGE LIBRARY
         attribute set, a PRODUCT SHOW OBJECT command will display all
         the IMAGE LIBRARY files at conflict.  This indicates incorrect
         entries to the PCSI database and may cause some problems.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  When a number of patch kits are installed and they contain
         files with the IMAGE LIBRARY attribute set, a PRODUCT SHOW
         OBJECT command may display inconsistent information,  i.e.,
         showing a file owned by one patch kit and the equivalent image
         library module owned by another patch kit.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
      o  When a number of patch kits are installed and they contain
         files with the IMAGE LIBRARY attribute set, a PRODUCT SHOW
         OBJECT command may display inconsistent information, i.e.,
         showing a file owned by one patch kit and the equivalent image
         library module owned by another patch kit.
    
         Images Affected:  [SYSLIB]PCSI$SHR.EXE
    
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS database.  To view these articles, open the appropriate
    product database and perform a query using either of the following
    search strings: 'DEC-AXPVMS-VMS72_PCSI-V0100.PCSI' or 'VMS72_PCSI-V0100'.
    
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    The system does not need to be rebooted after this kit is installed.
    However, all processes will need to log out and then back in to use
    the new PRODUCT command qualifiers and keywords.
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | PCSI$MAIN.EXE              | CD108F43 | X11.1           |  6-APR-2000  |
      |                                       |                 | 07:48:03.35  |
      +----------------------------+----------+-----------------+--------------+
      | PCSI$SHR.EXE               | 1F1C77DD | X11.1           |  6-APR-2000  |
      |                                       |                 | 07:47:54.44  |
      +----------------------------+----------+-----------------+--------------+
    
    
    All trademarks are the property of their respective owners.
    
privacy statement using this site means you accept its terms feedback to the webmaster
VMS rules VMS rocks OpenVMS rules OpenVMS rocks