Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS62TO71U2_PCSI-V0200 Alpha V6.2 - V7.1-2 PCSI ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
      
    Copyright (c) Compaq Computer Corporation 1998, 2000.  All rights reserved.
    
    Modification Date:  16-AUG-2000
    Modification Type:  DOCUMENTATION:  Technical Modification
                          Added note regarding VMS712_UPDATE-V0300
                          kit and possible PCSI executable confusion.
    
    OP/SYS:     OpenVMS Alpha
    
    COMPONENT:  PCSI
                  PCSI$MAIN.EXE
                  PCSI$SHR.EXE
    
    SOURCE:     Compaq Computer Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS62TO71U2_PCSI-V0200
                        DEC-AXPVMS-VMS62TO71U2_PCSI-V0200--4.PCSI
         ECO Kits Superseded by This ECO Kit:  VMS62TO71U2_PCSI-V0100
         ECO Kit Approximate Size:  3264 Blocks
         Kit Applies To:  OpenVMS Alpha V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3,
                                        V7.1, V7.1-1H1, V7.1-1H2, V7.1-2
         System/Cluster Reboot Necessary:  No
         Rolling Re-boot Supported:  Not Applicable
         Installation Rating:  INSTALL_2
                               2 - To be installed on all systems running
                                   the listed version(s) of OpenVMS and
                                   using the following feature(s):
    
                                   New PRODUCT command functionality
    
                                   Layered product installation instructions
                                   that require this remedial kit be
                                   installed as a prerequisite
    
         Kit Dependencies:
    
           The following remedial kit(s) must be installed BEFORE
           installation of this kit:
    
             None
    
           In order to receive all the corrections listed in this
           kit, the following remedial kits should also be installed:
    
             None
    
    NOTE:  This kit and the VMS712_UPDATE-V0300 kit both contain PCSI
           executable files and it appears as though this kit supersedes
           the files in the UPDATE kit.  Either of the kits can be
           installed first because PCSI will do the right thing and
           keep/install the latest executable.
    
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for PCSI on Alpha V6.2 through V7.1-2.
    
    New Functionality Included in VMS62TO71U2_PCSI-V0200 and
    VMS62TO71U2_PCSI-V0100:
    
      o  This remedial kit updates the POLYCENTER Software Installation
         utility of OpenVMS, including associated command procedures
         and help text.  After installation, the POLYCENTER Software
         Installation facility will be functionally equivalent to that
         provided by OpenVMS V7.2.  Changes include new PRODUCT
         commands and qualifiers, improved display of output from
         PRODUCT SHOW commands, features useful for product developers,
         and several for problems that have been fixed since OpenVMS
         V7.2 was release.
    
         After installation of this remedial kit your system will use
         the new features provided by this version of the POLYCENTER
         Software Installation utility.  If a layered product is
         installed that makes use of this new functionality, then it
         may not be possible to revert back to an older version of the
         utility.  This restriction occurs because there may be records
         in the software product database that the older version of the
         utility will not be able to interpret.  This scenario may
         occur after an OpenVMS upgrade to a version of OpenVMS prior
         to V7.1-2.  For example, this situation occurs if you:
    
           1.  Install this remedial kit on OpenVMS V6.2, V6.2-1H1,
               V6.2-1H2, V6.2-1H3, V7.1, V7.1-1H1, or V7.1-1H2
    
           2.  Install DWMOTIF V1.2-5
    
           3.  Upgrade to (or re-install) OpenVMS V6.2, V6.2-1H1,
               V6.2-1H2, V6.2-1H3, V7.1, V7.1-1H1, or V7.1-1H2
    
         The upgrade to any of the versions listed in #3 above may fail
         (or other PRODUCT command operations on the product database
         may fail) with one of the following errors:
    
           SYSTEM-F-ACCVIO, access violation, ...
    
                 or
    
           %PCSI-E-UNSDOCENC, unsupported product document encoding version
    
         To prevent these failures after installing this remedial kit
         and the DWMOTIF product (in the example above), do the
         following:
    
           1.  Remove DWMOTIF using the command:
    
                 $ PRODUCT REMOVE DWMOTIF
    
           2.  Upgrade to (or re-install) OpenVMS V6.2, V6.2-1H1,
               V6.2-1H2, V6.2-1H3, V7.1, V7.1-1H1, or V7.1-1H2
    
           3.  Re-install this remedial kit
    
           4.  Re-install DWMOTIF
    
         This workaround is not needed if you are upgrading to OpenVMS
         Alpha V7.1-2 or later.  These releases already include the new
         features provided by this remedial kit to eliminate this
         issue.
    
         Images Affected:
           -  [SYSEXE]PCSI$MAIN.EXE
           -  [SYSLIB]PCSI$SHR.EXE
           -  [SYSUPD]PCSI$CREATE_ACCOUNT.COM
           -  [SYSUPD]PCSI$CREATE_NETWORK_OBJECT.COM
           -  [SYSUPD]PCSI$CREATE_RIGHTS_IDENTIFIER.COM
           -  [SYSUPD]PCSI$DELETE_ACCOUNT.COM
           -  [SYSUPD]PCSI$DELETE_NETWORK_OBJECT.COM
           -  [SYSUPD]PCSI$DELETE_RIGHTS_IDENTIFIER.COM
           -  [SYSUPD]PCSI$EXTRACT_TLB.COM
           -  [SYSUPD]PCSI$REGISTER_PRODUCT.COM
           -  [SYSUPD]PCSI.CLD
           -  [SYSHLP]HELPLIB.HLB
    
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS database.  To view these articles, open the appropriate
    product database and perform a query using either of the following
    search strings: 'DEC-AXPVMS-VMS62TO71U2_PCSI-V0200.PCSI' or
    'VMS62TO71U2_PCSI-V0200'.
    
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    The system does not need to be rebooted after this kit is installed.
    However, all processes will need to log out and then back in to use
    the new PRODUCT command qualifiers and keywords.
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | PCSI$MAIN.EXE              | DC03F55F | X11.1           | 14-MAR-2000  |
      |                                       |                 | 15:40:00.31  |
      +----------------------------+----------+-----------------+--------------+
      | PCSI$SHR.EXE               | 9EC8BB7C | X11.1           | 14-MAR-2000  |
      |                                       |                 | 15:39:47.06  |
      +----------------------------+----------+-----------------+--------------+
    
    
    All trademarks are the property of their respective owners.
    
privacy statement using this site means you accept its terms feedback to the webmaster
VMS rules VMS rocks OpenVMS rules OpenVMS rocks