Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

ROBOTE01014 Media Robot Utility for OpenVMS Alpha ECO Summa

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
      
    Copyright (c) Compaq Computer Corporation 2000.  All rights reserved.
    
    Modification Date:  24-MAY-2000
    Modification Type:  New Kit
    
    PRODUCT:    Media Robot Utility for OpenVMS Alpha
    
    OP/SYS:     OpenVMS Alpha
    
    SOURCE:     Compaq Computer Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  ROBOTE01014
         ECO Kits Superseded by This ECO Kit:  None
         ECO Kit Approximate Size:  13,140 Blocks
                        Saveset A - 11,412 Blocks
                        Saveset B -    576 Blocks
                        Saveset C -  1,152 Blocks
    
         Kit Applies To:  Media Robot Utility V1.4
                          OpenVMS Alpha V6.2, V6.2-1H1, V6.2-1H2,
                                        V7.1, V7.1-1H1, V7.1-1H2,
                                        V7.2, V7.2-1
         System/Cluster Reboot Necessary:  Information Not Available
         Rolling Re-boot Supported:  Information Not Available
         Installation Rating:  INSTALL_UNKNOWN
    
         Kit Dependencies:
    
           The following remedial kit(s) must be installed BEFORE
           installation of this kit:
    
             None
    
           In order to receive all the corrections listed in this
           kit, the following remedial kits should also be installed:
    
             None
    
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for the Media Robot Utility on OpenVMS Alpha V6.2
    through V7.2-1.  This kit addresses the following problems:
    
      o  In case of an ESL 9000(multitower) with 3 units of
         ESL9326D, 'read element status'(RES) for SLOTS could not be
         issued. This problem was noticed with respect to the
         "robot find cartridge" command.
    
         The problem was analysed to occur due to a VMS imposed restriction
         that RES could return data of length 64K or less only.
         In case of the ESL9326D the returned data length would be
         978 X 88 = 86064.
    
         The fix for this problem involved capturing return values
         larger than the allowed length, in parts and thus
         fitting the RES of the SLOTS within the permitted length.
    
      o  In case of a multitude of PORTS in use, time taken for
         GUI and CLI commands to execute used to be high because
         of too many RES in use. This problem has been fixed in
         this ECO by the use of a single RES instead of many.
    
      o   The MRU-UNIX command "robot show drive", showed drives of
          only one unit, as "Available". This problem has been
          fixed in this ECO, all drives will now be "available".
    
      o  New Features:
         -------------
    
         New functionality comprises, additional support for the following:
    
           a) TSL10000
           b) SSL2000
           c) Tru64 UNIX V4.0G
           d) Tru64 Unix V5.0 and 5.0A (with restrictions. For details
              refer refer to Chapter 3 of COMPAQ Media Robot Utility - Guide
              to Installation, Connectivity, and Operation.)
    
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS and APPL_TOOLS databases.  To view these articles,
    open the appropriate product database and perform a query using either
    of the following search strings: 'ROBOTE01014' or 'ROBOT'.
      
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    The images in this kit will not take effect until the system is
    rebooted.  If there are other nodes in the VMScluster, they must
    also be rebooted in order to make use of the new image(s).
    
    All trademarks are the property of their respective owners.
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | MRD$RTL.EXE                |%X7EF578C8| MRU V1.4-1      |  5-MAY-2000  |
      |                                       |                 | 17:30:11.25  |
      +----------------------------+----------+-----------------+--------------+
      | ROBOT$MESSAGE.EXE          |%X22B4A35D| 0               |  5-MAY-2000  |
      |                                       |                 | 17:40:29.17  |
      +----------------------------+----------+-----------------+--------------+
      | ROBOT.EXE                  |%XB53BB633| MRU V1.4-1      |  5-MAY-2000  |
      |                                       |                 | 17:30:15.43  |
      +----------------------------+----------+-----------------+--------------+
      | XROBOT.EXE                 |%X4319A4EB| MRU V1.4-1      |  5-MAY-2000  |
      |                                       |                 | 17:40:25.12  |
      +----------------------------+----------+-----------------+--------------+
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | MRD$RTL.EXE                | 2C8F2C6A | MRU V1.4-1      |  5-MAY-2000  |
      |                                       |                 | 17:53:15.25  |
      +----------------------------+----------+-----------------+--------------+
      | ROBOT$MESSAGE.EXE          | 22B4A35D | 0               |  5-MAY-2000  |
      |                                       |                 | 18:01:03.13  |
      +----------------------------+----------+-----------------+--------------+
      | ROBOT.EXE                  | 331B3973 | MRU V1.4-1      |  5-MAY-2000  |
      |                                       |                 | 17:53:16.82  |
      +----------------------------+----------+-----------------+--------------+
      | XROBOT.EXE                 | 96F14D62 | MRU V1.4-1      |  5-MAY-2000  |
      |                                       |                 | 17:59:51.52  |
      +----------------------------+----------+-----------------+--------------+
    
privacy statement using this site means you accept its terms feedback to the webmaster
VMS rules VMS rocks OpenVMS rules OpenVMS rocks