Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS731_GRAPHICS-V0200 ATI RADEON 7500 Graphics adapter ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
    
    
    New Kit Date:       16-JUN-2003
    Modification Date:  Not Applicable
    Modification Type:  NEW KIT
    
    Copyright (c) Hewlett-Packard Company 2002,2003.  All rights reserved.
    
    OP/SYS:     OpenVMS Alpha
    
    COMPONENT:  Graphics
    
    SOURCE:     Hewlett-Packard Company
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS731_GRAPHICS-V0200
                        DEC-AXPVMS-VMS731_GRAPHICS-V0200--4.PCSI
         ECO Kits Superseded by This ECO Kit: VMS731_GRAPHICS-V0100
         ECO Kit Approximate Size:  18048 Blocks
         Kit Applies To:  OpenVMS Alpha V7.3-1
         System/Cluster Reboot Necessary:  Yes
         Rolling Re-boot Supported:  Yes
         Installation Rating:  INSTALL_2
                                2 : To  be  installed  by   all  customers  using  the                                 following feature(s):
    
    			        ATI RADEON 7500 Graphics Adapter
    
         Kit Dependencies:
    
           The following remedial kit(s), or later, must be installed BEFORE
           installation of this, or any required kit:
    
             None
    
           In order to receive all the corrections listed in this
           kit, the following remedial kits should also be installed:
    
             None
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for ATI RADEON 7500 Graphics adapter support on
    OpenVMS Alpha V7.3-1.
    
    
         o  PROBLEMS ADDRESSED IN VMS731_GRAPHICS-V0200 KIT
    
            The system could crash when the DECWindows server is started.
            Typically,the crash is an INVEXCEPTN BUGCHECK @SYS$GHDRIVER+n
            where n is one of several different possible address offsets.
    
            Also, the system can hang if SYSTEM_CHECK or POOLCHECK is set
            to 1.
    
            Images Affected: [SYS$LDR]SYS$GHDRIVER.EXE (new image)
    
    
    
    NEW FUNCTIONALITY INTRODUCED IN THE VMS731_GRAPHICS-V0100 KIT
    
    
         o  This kit contains the 2D and 3D graphics software to support
            the ATI RADEON 7500 AGP and PCI graphics cards on OpenVMS
            Alpha Version 7.3-1.  The part numbers are as follows:
    
                         AGP card: 3X-PBXGG-AB
                         PCI card: 3X-PBXGG-AA
                         Open3D license: QL-0ADA9-AA
    
                                *** NOTE ***
    
            This kit ships with full support for the AGP card; the PCI
            card is still being tested.  When PCI qualification is
            completed, it will be announced on the "What's New" website.
            You can reach this by clicking on "what's new on our site" on
            the following webpage:
    
                         http://www.hp.com/go/openvms
    
            Currently, the PCI card is supported on the AlphaServer DS10.
            Support on other platforms will be announced as they are
            tested.  For updates on support for the AGP and PCI cards,
            refer to the QuickSpecs webpage at:
    
              http://h18000.www1.hp.com/products/quickspecs/Division/10410.html
    
            Full release notes for the ATI RADEON 7500 Graphics Support
            are supplied in HTML, PDF, and text format and are located in
            the SYS$HELP directory after this software kit is installed:
    
                   RADEON_7500_V1_README.HTML
                   RADEON_7500_V1_README_CONTENTS.HTML
                   RADEON_7500_V1_README.PDF
                   RADEON_7500_V1_README.TXT
    
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS database(s).  To view these articles,
    open the appropriate product database and perform a query using either
    of the following search strings: 'VMS731_GRAPHICS' or
    'VMS731_GRAPHICS-V0200'.
    
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    This kit requires a system reboot.  HP strongly recommends that a
    reboot is performed immediately after kit installation to avoid
    system instability
    
    If you have other nodes in your OpenVMS cluster, they must also be
    rebooted in order to make use of the new image(s).  If it is not
    possible or convenient to reboot the entire cluster at this time, a
    rolling re-boot may be performed.
    
    INSTALLATION INSTRUCTIONS:
    
    Install this kit with the POLYCENTER Software installation utility
    by logging into the SYSTEM account, and typing the following at the
    DCL prompt:
    
       PRODUCT INSTALL VMS731_GRAPHICS /SOURCE=[location of Kit]
    
    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.
    
    Additional help on installing PCSI kits can be found by typing
       HELP PRODUCT INSTALL at the system prompt
    
    
    Special Installation Instructions:
    
         o  Scripting of Answers to Installation Questions
    
                        During installation, this kit will ask and require user
              response to several questions.  If you wish to automate the
              installation of this kit and avoid having to provide responses
              to these questions, you must create a DCL command procedure
              that includes the following definitions and commands:
    
               -  $ DEFINE/SYS NO_ASK$BACKUP TRUE
    
               -  $ DEFINE/SYS NO_ASK$REBOOT TRUE
    
               -  Add the following qualifiers to the PRODUCT INSTALL
                  command and add that command to the DCL procedure.
    
                    /PROD=DEC/BASE=AXPVMS/VER=V2.0
    
    
               -  De-assign the logicals assigned
    
              For example, a sample command file to install the
              VMS731_GRAPHICS-V0200 kit would be:
    
              $
              $ DEFINE/SYS NO_ASK$BACKUP TRUE
              $ DEFINE/SYS NO_ASK$REBOOT TRUE
              $!
              $ PROD INSTALL VMS731_GRAPHICS/PROD=DEC/BASE=AXPVMS/VER=2.0
              $!
              $ DEASSIGN/SYS NO_ASK$BACKUP
              $ DEASSIGN/SYS NO_ASK$REBOOT
              $!
              $ exit
    
    All trademarks are the property of their respective owners.
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | DECW$DRM_RADEON.EXE        | C79472D6 | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:13:14.02  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$OPENGLSHR_RADEON.EXE  | E3724379 | DW V7.3-030404  |  4-APR-2003  |
      |                                       |                 | 08:23:33.97  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$OPENGLUSHR_V11.EXE    | 9FBB4CCB | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:24:38.26  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$OPENGLUTSHR.EXE       | 04D0C8BB | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:27:23.80  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$SERVER_DDX_FB.EXE     | 58AB61CD | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:37:31.46  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$SERVER_DDX_RADEON.EXE | C205A732 | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:42:27.63  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$SERVER_DDX_XAA.EXE    | 9252B698 | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:37:51.61  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$SERVER_DIX.EXE        | 661E840E | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:08:46.94  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$SERVER_DRI.EXE        | 2711559B | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:42:22.94  |
      +----------------------------+----------+-----------------+--------------+
      | DECW$SVEXT_GLX_RADEON.EXE  | 91BA4D34 | DW V7.3-030312  | 12-MAR-2003  |
      |                                       |                 | 13:32:52.50  |
      +----------------------------+----------+-----------------+--------------+
      | RADEON_STATUS.EXE          | 58913666 | V1.0            | 12-MAR-2003  |
      |                                       |                 | 13:14:34.74  |
      +----------------------------+----------+-----------------+--------------+
      | SYS$CPU_ROUTINES_2608.EXE  | F0D5F280 | X-1             | 16-JAN-2003  |
      |                                       |                 | 08:25:26.29  |
      +----------------------------+----------+-----------------+--------------+
      | SYS$CPU_ROUTINES_270F.EXE  | 37C28994 | X-1             | 14-FEB-2003  |
      |                                       |                 | 16:27:54.13  |
      +----------------------------+----------+-----------------+--------------+
      | SYS$GHDRIVER.EXE           | 4AA1EC98 | DW V7.          | 5-JUN-2003   |
      |                                       |                 | 14:43:58.74  |
      +----------------------------+----------+-----------------+--------------+
      | SYS$IKUDRIVER.EXE          | FEBA83FD | DW V7.          | 12-MAR-2003  |
      |                                       |                 | 13:28:32.91  |
      +----------------------------+----------+-----------------+--------------+
    
privacy statement using this site means you accept its terms feedback to the webmaster
VMS rules VMS rocks OpenVMS rules OpenVMS rocks