IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS712_CLIUTL-V0100 Alpha V7.1-2 CLIUTL ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
      
    
    Copyright (c) Compaq Computer Corporation 2000.  All rights reserved.
    
    Modification Date:  17-JAN-2001
    Modification Type:  New Kit
    
    OP/SYS:  OpenVMS Alpha
    
    COMPONENT: CLIUTL
    
    SOURCE:     Compaq Computer Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS712_CLIUTL-V0100
                        DEC-AXPVMS-VMS712_CLIUTL-V0100--4.PCSI
         ECO Kits Superseded by This ECO Kit:  None
         ECO Kit Approximate Size:  2048
         Kit Applies To:  OpenVMS Alpha V7.1-2
         System/Cluster Reboot Necessary:  No
         Rolling Re-boot Supported:  Information Not Available
         Installation Rating:  3
    
         Kit Dependencies:
    
           The following remedial kit(s) must be installed BEFORE
           installation of this kit:
    
               VMS712_UPDATE-V0300
               VMS62TO71U2_PCSI-V0200
    
           In order to receive all the corrections listed in this
           kit, the following remedial kits should also be installed:
    
             VMS712_RMS-V0100
    
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for CLIUTL on OpenVMS Alpha V7.1-2.  This kit addresses
    the following problems:
    
    Problems Addressed In VMS712_CLIUTL-V0100:
    
       o   A  SET  DEVICE/SERVED  <TAPEDEV>  command  may  fail  with   a
           %SYSTEM-F-IVDEVNAM  error.   This  problem could occur when an
           ALPHA system is mistakenly  booted  with  a  SYSGEN  parameter
           TMSCP_SERVE_ALL = 0.  As a result, none of the tape drives are
           served to the cluster clients.  Consequently, typing  the  SET
           DEVICE/SERVED  <TAPEDEV>  command  fails.   Since  the  SYSGEN
           parameter is not dynamic, a reboot of the server is  necessary
           to make the tape devices available to the client nodes.
    
           This change extends functionality of the SET DEVICE/SERVED  on
           ALPHA servers to include tape devices.
    
               Images Affected:  [SYSEXE]SET.EXE
    
      
       o   If the  $SET  AUDIT/SERVER=START  command  fails,  the  system
           STARTUP   process   will  hang  in  a  loop  waiting  for  the
           AUDIT_SERVER process to start.
    
               Images Affected:  [SYSEXE]SETAUDIT.EXE
    
    
       o   When an unprivileged user attempts to access a  queue  and  is
           denied, the event is not alarmed or audited.
    
               Images Affected:  [SYSEXE]SUBMIT.EXE
    
    
       o   Add a new /CONTENTION_POLICY qualifier to SET  RMS_DEFAULT  to
           address locking fairness issues.
    
           The new Alpha global buffer read-mode lock support  introduced
           in V7.2-1H1 is functionally compatible with both VAX and older
           Alpha releases.  Operations in mixed clusters produce  correct
           results.   However, there is a locking fairness issue that may
           arise with mixed cluster operations.
    
           In a mixed cluster environment with very high  contention  for
           specific  buckets, it is possible for accesses to write-shared
           files on nodes using  read-mode  bucket  locking  to  dominate
           access  to  a  bucket.   Nodes  without  this support might be
           unable to access the bucket for a protracted period  of  time.
           It  is  also  possible  to  observe comparable behavior on all
           OpenVMS versions when dealing with  accesses  to  write-shared
           files  without  global buffers enabled -- even on a standalone
           system.  A similar fairness issue between lock conversions and
           new  lock  requests  may  be  observed  in  which the new lock
           requests may remain un-granted for an extended period of time.
    
           This kit provides an interface  for  RMS  support  for  a  new
           option  to  improve  fairness under high contention conditions
           for write-shared files.  The option is  controlled  using  the
           /CONTENTION_POLICY   qualifier   to   the   DCL   command  SET
           RMS_DEFAULT.  The option may be set at  a  process  or  system
           level.   Since  selecting  this option may noticeably increase
           locking  overhead  and  since  many  applications  will  never
           encounter  this issue, the default system behavior leaves this
           option disabled.  A future lock management enhancement  should
           make this fairness workaround unnecessary for later releases.
    
           The  following  are  valid  PROCESS  keywords   (/SYSTEM   not
           specified) for SET RMS_DEFAULT/CONTENTION_POLICY:
    
              NEVER           Never use the higher overhead option to
                              improve fairness for any write-shared files
                              accessed by this process;  minimal
                              overhead.
    
              SOMETIMES       Use this option for fairer bucket access
                              (but higher overhead) to any write-shared
                              files with global buffers enabled that are
                              accessed by this process.
    
              ALWAYS          Use this option for fairer bucket access
                              (but higher overhead) to all write-shared
                              files accessed by this process.
    
              SYSTEM_DEFAULT  Use system setting. Note that this keyword
                (Default)     is disallowed with /SYSTEM.
    
           The following are valid SYSTEM keywords (/SYSTEM specified):
    
              NEVER           (Default) Never use the higher overhead
                              option to improve fairness for any
                              write-shared files accessed on the system;
                              minimal overhead.
    
              SOMETIMES       Use this option for fairer bucket access
                              (but higher overhead) to any write-shared
                              files with global buffers enabled that are
                              accessed on the system.
    
              ALWAYS          Use this option for fairer bucket access
                              (but higher overhead) to all write-shared
                              files accessed on the system.
    
              Images Affected:  [SYSEXE]SET.EXE
    
       o    SHOW LOGICAL allocates virtual address space based on pagesize
            rather  than  pagelet  size  for Alpha only.  De-allocation of
            used virtual memory was incorrect.
    
               Images Affected:  [SYSEXE]SHOW.EXE
    
    
       o    If the virtual-circuit (PB$  path-block)  count  exceeds  four
            times  the SCS-node count, a SHOW CLUSTER command will hang on
            startup on cluster nodes with many  SCS  ports,  e.g.,  CIPCA,
            CIXCD, MC:...  or Pxx0:  devices.  An "SCS-node" is defined as
            any   SCS-speaking   node,   such   as   HSJxx/HSCxx   Storage
            Controllers, RFxx DSSI disk controllers, or VMS nodes, etc.
    
               Images Affected:  [SYSEXE]SHWCLSTR.EXE
    
    
      
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS database.  To view these articles, open the appropriate
    product database and perform a query using either of the following
    search strings: 'VMS712_CLIUTL-V0100' or 'VMS712_CLIUTL'.
    
      
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    No reboot is necessary after successful installation of  this  kit.
    However, users must log out and log back in to use the new features
    provided by this kit.
    
    Install this kit with the POLYCENTER Software installation  utility
    by logging into the SYSTEM account, and typing the following at the
    DCL prompt:
    
       PRODUCT INSTALL VMS712_CLIUTL /SOURCE=[location of Kit]
    
    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.
    
    Additional help on installing PCSI kits can be found by typing
    HELP PRODUCT INSTALL at the system prompt
    
    All trademarks are the property of their respective owners.
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | CLIUTLMSG.EXE              | 36ADDA6D | X-3             |  7-DEC-2000  |
      |                                       |                 | 17:14:22.78  |
      +----------------------------+----------+-----------------+--------------+
      | SET.EXE                    | 8845EEE2 | X-4             |  7-DEC-2000  |
      |                                       |                 | 17:13:42.45  |
      +----------------------------+----------+-----------------+--------------+
      | SETAUDIT.EXE               | A13549A2 | X-12            |  7-DEC-2000  |
      |                                       |                 | 17:13:57.68  |
      +----------------------------+----------+-----------------+--------------+
      | SHOW.EXE                   | 19810A58 | X-1             |  7-DEC-2000  |
      |                                       |                 | 17:13:30.22  |
      +----------------------------+----------+-----------------+--------------+
      | SHWCLSTR.EXE               | 3426DD6E | X-22            |  7-DEC-2000  |
      |                                       |                 | 17:13:53.85  |
      +----------------------------+----------+-----------------+--------------+
      | SUBMIT.EXE                 | CB65BB51 | X-27            |  7-DEC-2000  |