Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
ALPDWXT01_070 DECW$XTDRIVER (Alpha) ECO Summary
Copyright (c) Digital Equipment Corporation 1994, 1996. All rights reserved.
PRODUCT: OpenVMS Alpha
COMPONENT: DECW$XTDRIVER.EXE
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: ALPDWXT01_070
ECO Kits Superseded by This ECO Kit: AXPDWXT01_061 (AXPDWXT)
ECO Kit Approximate Size: 440 Blocks
Saveset A - 162 Blocks
Saveset B - 90 Blocks
Saveset C - 90 Blocks
Saveset D - 90 Blocks
Kit Applies To: OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2,
V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3,
V7.0
This kit no longer supports OpenVMS V1.5*
(AXPDWXT01_015). If you are using OpenVMS Alpha
V1.5* and need the fixes contained in this kit, it
is recommended that you upgrade to a later version
of OpenVMS Alpha.
System/Cluster Reboot Necessary: Yes
ECO KIT SUMMARY:
An ECO kit exists for OpenVMS Alpha V6.1 through V7.0. This kit
addresses the following problems:
Problems Addressed in the ALPDWXT01_070 Kit:
o EV4 and later CPU modules in a multiple CPU environment, will cause
VXT2000 window users (using the LAT transport protocol) to lose all
DECterm's, clocks, calendars, Bookreader, etc. Only Session Manager
remains.
Problems Addressed in the AXPDWXT01_061 Kit for OpenVMS Alpha V6.1,
V6.1-1H1:
o When a LAT connection is lost because of a network interruption,
XTDRIVER posts the same IRP twice to I/O postprocessing, corrupting
the I/O postprocessing queue and possibly resulting in a SSRVEXCEPTN
crash.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in the
OPENVMS databases. To view these articles, open the appropriate product
database and perform a query using the search strings: 'ALPDWXT01_070'
or 'ALPDWXT'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
In order for the corrections in this kit to take effect, the system must
be rebooted. If the system is a member of a VMScluster, the entire
cluster should be rebooted.
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| SYS$XTDRIVER.EXE | E87EE842 | DECW X2-BL6 | 25-JUL-1996 |
| | | 13:56:53.99 |
+----------------------------+----------+-----------------+--------------+
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| SYS$XTDRIVER.EXE | E899F3FC | DECW X2-BL6 | 13-AUG-1996 |
| | | 01:13:13.18 |
+----------------------------+----------+-----------------+--------------+
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| SYS$XTDRIVER.EXE | 7AA41FAA | DECW X2-BL6 | 29-AUG-1996 |
| | | 03:55:42.09 |
+----------------------------+----------+-----------------+--------------+
|