Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS712_CPU2208-V0200 Alpha V7.1-2 CPU Routines 2208/2508 ECO Summa

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
      
    New Kit Date     :  06-FEB-2001
    Modification Date:  Not Applicable
    Modification Type:  Updated Kit. Supersedes VMS712_CPU2208-V0100
    
      
    Copyright (c) Compaq Computer Corporation 2000.  All rights reserved.
    
    OP/SYS:     OpenVMS Alpha
    
    COMPONENT:  CPU Routines
    
    SOURCE:     Compaq Computer Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS712_CPU2208-V0200
         ECO Kits Superseded by This ECO Kit:  VMS712_CPU2208-V0100
                                               VMS712_DS20E-V0100
         ECO Kit Approximate Size:  654 Blocks
         Kit Applies To:  OpenVMS Alpha V7.1-2
         System/Cluster Reboot Necessary:  Yes
         Rolling Re-boot Supported:  Yes
         Installation Rating:  INSTALL_2
                               2 - To be installed on the following systems:
    
               AlphaServers            AlphaStations
               -------------------     --------------------------------------
    
               Compaq AlphaServer      Compaq AlphaStation ES40
               ES40
    
               Compaq AlphaServer      Compaq AlphaStation XP900
               DS10
    
               Compaq AlphaServer      Compaq AlphaStation XP1000
               DS10L
    
               Compaq AlphaServer      Compaq AlphaStation 21264 PCI/ISA SBC
               DS20
    
               Compaq AlphaServer      Compaq AlphaStation DS20E
               DS20E
    
    
         Kit Dependencies:
    
           The following remedial kit(s) must be installed BEFORE
           installation of this kit:
    
             VMS712_UPDATE-V0100
             VMS62TO71U2_PCSI-V0200
             VMS712_LAN-V0100
      
           In order to receive all the corrections listed in this
           kit, the following remedial kits should also be installed:
    
             None
    
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for CPU Routines 2208 and 2508 on OpenVMS Alpha V7.1-2.
    This kit addresses the following problems:
    
    PROBLEMS ADDRESSED IN VMS712_CPU2208-V0200 KIT
    
      o  The VMS712_DS20E-V0100 and VMS712_CPU2208-V0100 remedial  kits
         contained  common images.  The VMS712_CPU2208-V0200 kit simply
         combines these two kits.  If you have  already  installed  the
         VMS712_DS20E-V0100   and  VMS712_CPU2208-V0100  remedial  kits
         there is no need to install this VMS712_CPU2208-V0200 kit.
    
    PROBLEMS ADDRESSED IN VMS712_CPU2208-V0100 KIT
    
      o  Allow mixed CPU operation in support of field replacements.
         This allows field replacement of CPUs without having to
         replace all the CPUs in the system.
    
           Images Affected:  [SYS$LDR]SYS$CPU_ROUTINES_2208.EXE
    
      o  A potential data inconsistency has been identified on some
         systems (referenced below) during qualification testing of
         an unreleased graphics software kit.  This error has only
         occurred in a highly stressful technical validation environment.
         Compaq does not expect customers to experience this problem, but
         in an effort to provide the highest level of customer service, we
         recommend that users with the following systems install the
         DEC-AXPVMS-VMS721_CPU2208-V0100-4.PCSI (or later) or
         DEC-AXPVMS-VMS712_CPU2208-V0100-4.PCSI (or later) remedial kits:
    
           AlphaServers            AlphaStations
           -------------------     --------------------------------------
    
           Compaq AlphaServer      Compaq AlphaStation ES40
           ES40
    
           Compaq AlphaServer      Compaq AlphaStation XP900
           DS10
    
           Compaq AlphaServer      Compaq AlphaStation XP1000
           DS10L
    
           Compaq AlphaServer      Compaq AlphaStation 21264 PCI/ISA SBC
           DS20
    
           Compaq AlphaServer      Compaq AlphaStation DS20E
           DS20E
    
           ----------------------------------------------------------------
    
           For OpenVMS Version 7.2-1H1, this fix is also included in the
           DEC-AXPVMS-VMS721H1_UPDATE-V0300 (or_later) remedial kit.
    
           Images Affected:
             -  [SYS$LDR]SYS$CPU_ROUTINES_2208.EXE
             -  [SYS$LDR]SYS$CPU_ROUTINES_2508.EXE
    
    NEW FUNCTIONALITY ADDRESSED IN VMS721_DS20E_ES40-V0100 KIT
    
      o  Compaq AlphaServer DS20E Support
    
         This kit provides OpenVMS Version  7.1-2  support  for  the  Compaq
         AlphaServer  DS20E.   The  DS20E  is  a  follow-on  to  the  Compaq
         AlphaServer DS20.  This kit includes the following OpenVMS  support
         on the DS20E:
    
          o  Server management
    
          o  3X-DEPVD-AA PCI adapter
    
          o  IDE CD-ROM and boot and runtime
    
    
         Image(s) Affected:
    
          -  [SYS$LDR]SYS$CPU_ROUTINES_2208.EXE
    
          -  [SYS$LDR]SYS$IIDRIVER.EXE
    
          -  [SYSEXE]SYS$SMHANDLER.EXE
    
    
    
      o  DS20E Restrictions
    
         I/O to Tribytes in PCI Space Unsupported
    
         On Compaq  AlphaServer  DS20E  systems,  you  cannot  use  the
         following  system  routines  to  perform I/O tribyte reads and
         writes:
    
               o  IOC$READ_PCI_CONFIG
    
               o  IOC$WRITE_PCI_CONFIG
    
               o  IOC$READ_IO
    
               o  IOC$WRITE_IO
    
         If a device driver calls any of these system routines  with  a
         length  of  three,  you  must use one of the following methods
         instead-depending on your I/O cards characteristics:
    
         For IOC$READ_IO and IOC$READ_PCI_CONFIG:
    
          o  Use a longword read, and mask out the byte.
    
          o  Do a combination of word and byte reads,  and  append  the
             data.
    
          For IOC$WRITE_IO and IOC$WRITE_PCI_CONFIG:
    
          o  Read a longword,  modify  the  tribyte,  and  rewrite  the
             longword.
    
         Note that AlphaServer  8200/8400  and  GS60/140  systems  with
         Alpha 21264 CPUs support tribyte reads and writes.
    
    
           o    I/O to Unaligned Words in PCI Space is Not Allowed
    
         This note applies to Compaq AlphaServer DS20E  systems.   When
         device   drivers   call  the  IOC$CRAM_CMD,  IOC$READ_IO,  and
         IOC$WRITE_IO  system   routines   with   the   IOC$K_WORD   or
         IOC$K_WORD_LANED  parameters,  the  I/O  address  must be on a
         natural, word-aligned boundary.   (In  other  words,  the  I/O
         address must be an even number).  If the I/O address is an odd
         number, these system routines return SS$_BADPARAM.
    
         Use AUTOGEN with Feedback to  Resize  ERLBUFFERPAGES  for  FRU
         Configuration Error Log Entry
    
         The FRU configuration tree provided by the Compaq  AlphaServer
         DS20E  console  firmware is not copied to the errorlog file if
         the SYSGEN parameter ERLBUFFERPAGES is not large enough.   Use
         the  following command to run AUTOGEN with the FEEDBACK option
         to   automatically   calculate   the   correct   setting    of
         ERLBUFFERPAGES  and  resize  the SYS$ERRORLOG.DMP file for the
         configuration error log entry.
    
            $ @SYS$UPDATE:AUTOGEN SAVPARAMS REBOOT FEEDBACK
    
    
         hl 3 Server Management Event Handler  Driver  and  Process  on
         Compaq   AlphaServer   DS20E   OpenVMS   Alpha  Version  7.1-2
         automatically  starts  the  Server  Management  Event  handler
         driver  and  process on Compaq AlphaServer DS20E systems.  The
         SMHANDLER process spends most of the  time  in  the  hibernate
         state.  When a Server Management Event occurs, an interrupt is
         delivered to the system specific  handler,  which  parses  the
         exception  frame  and  notifies  SMDRIVER  that  an  event has
         occurred.  The driver then delivers an AST  to  the  SMHANDLER
         process  with  the  event type.  The SMHANDLER process reports
         signaled    events     in     the     process     log     file
         SYS$MANAGER:SMHANDLER.LOG   and   with   an   OPCOM   message.
         Additional information about the  event  is  recorded  in  the
         system error log file.
    
         The SMHANDLER process may produce one of following new  system
         error messages:
    
           o  %SMHANDLER-S-STARTUP,  server  management  event   handler
              startup
    
           o  %SMHANDLER-W-RFF, redundant fan failure detected
    
           o  %SMHANDLER-W-RPS, redundant power supply failure detected
    
           o  %SMHANDLER-W-TEMP, warning temperature exceeded
    
         To correct the problem, the system manager should  schedule  a
         system  shutdown at a convenient time and request Compaq Field
         Service to replace the failing  hardware  component.   In  the
         meantime, the system will continue, but without the protection
         of the redundant hardware.
    
    
      o  Support for the 3X-DEPVD-AA PCI Adapter and TCP/IP for OpenVMS
    
         TCP/IP for OpenVMS  Version  4.2  does  not  support  the  new
         3X-DEPVD-AA  PCI  adapter  on the AlphaServer DS20E.  Prior to
         running UCX$CONFIG procedures, use the  following  command  to
         manually configure TCP/IP with the new ethernet adapter:
    
            _$ /INTERNET_INTERFACE=I /TYPE=(ETHERNET,CLUSTER) -
            _$ /INTERNET_INTERFACE=I /TYPE=(ETHERNET,CLUSTER) -
            _$ /DESCRIPTION=INTEL_ETHERNET
    
          Check with your Compaq  support  representative  if  you  have
          further questions on TCP/IP and the 3X-DEPVD-AA PCI adapter.
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS database.  To view these articles, open the appropriate
    product database and perform a query using either of the following
    search strings: 'VMS712_CPU2208-V0200' or 'VMS712_CPU2208'.
      
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    This kit requires a system reboot.  Compaq strongly recommends that
    a  reboot  is performed immediately after kit installation to avoid
    system instability
    
    If you have other nodes in your OpenVMS cluster, they must also  be
    rebooted  in  order  to make use of the new image(s).  If it is not
    possible or convenient to reboot the entire cluster at this time, a
    rolling re-boot may be performed.
    
    INSTALLATION INSTRUCTIONS:
    
    Install this kit with the POLYCENTER Software installation  utility
    by logging into the SYSTEM account, and typing the
    
    following at the DCL prompt:
    
    PRODUCT INSTALL VMS712_CPU2208 /SOURCE=[location of Kit]
    
    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.
    
    Additional help on installing PCSI kits can be found by typing
    HELP PRODUCT INSTALL at the system prompt
    
    All trademarks are the property of their respective owners.
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | SYS$CPU_ROUTINES_2208.EXE  | 95CC89E2 | X-1             | 12-SEP-2000  |
      |                                       |                 | 04:29:20.35  |
      +----------------------------+----------+-----------------+--------------+
      | SYS$CPU_ROUTINES_2508.EXE  | 15117819 | X-1             | 12-SEP-2000  |
      |                                       |                 | 04:29:20.32  |
      +----------------------------+----------+-----------------+--------------+
      | SYS$IIDRIVER.EXE           | 31E5B55C | X-1B2A1A1       | 29-JUL-1999  |
      |                                       |                 | 00:26:18.99  |
      +----------------------------+----------+-----------------+--------------+
      | SYS$SMHANDLER.EXE          | DBEF233B | X-5             | 26-AUG-1999  |
      |                                       |                 | 20:38:22.33  |
      +----------------------------+----------+-----------------+--------------+
    
privacy statement using this site means you accept its terms feedback to the webmaster
VMS rules VMS rocks OpenVMS rules OpenVMS rocks