Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

DNVOSI_ECO04061 For OpenVMS VAX ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
    
    
    Copyright (c) Digital Equipment Corporation 1995. All rights reserved.
    
    PRODUCT:    DECnet/OSI V6.1 for OpenVMS VAX
    
    OP/SYS:     OpenVMS VAX
    
    SOURCE:     Digital Equipment Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  DNVOSI_ECO04061
         ECO Kits Superseded by This ECO Kit:  DNVOSI_ECO03061
                                               DNVOSI_ECO01061
         ECO Kit Approximate Size:  7010 Blocks
         Kit Applies To:  DECnet/OSI V6.1 for OpenVMS VAX
                          OpenVMS VAX V6.1
    
                          NOTE:  To verify that the you are running the
                                 correct version of DECnet/OSI, enter the
                                 following NCL command:
    
                                    NCL Show Implementation
    
         System Reboot Necessary:  Yes
    
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for DECnet/OSI V6.1 for OpenVMS VAX on OpenVMS VAX V6.1.
    This kit addresses the following problems.
    
      Corrections for BASE Components:
    
      o  Image SYS$LIBRARY:CDI$SHR.EXE
    
         -  Correct local 'simple name' processing.
         -  Correct error returned to Session for NET$ACP processing.
    
      o  Image SYS$SYSTEM:NET$ACP.EXE
    
         -  Include for CDI$SHR.EXE.
    
      o  Image SYS$UPDATE:NET$CONVERT_DATABASE.EXE
    
         -   Remove the illegal FDDI command for Station Buffers that
             prevented startup.
    
      o  Image SYS$LOADABLE_IMAGES:NET$DRIVER.EXE
    
         -  Fix pool leak where VCRPs fail to be deallocated.
         -  Notify the $QIO interface when the incoming connection timer
            expires and the incoming connection has not been explicitly
            accepted or rejected by the target task.
    
      o  Image SYS$LOADABLE_IMAGES:NET$OSDRIVER.EXE
    
         -  Include with NET$DRIVER.
    
      o  Image SYS$LOADABLE_IMAGES:NET$ROUTING_ES.EXE
    
         -  On a single circuit prevent unnecessary probe packets.
         -  On a point-to-point circuit a stale PDU size and pointer were
            used for the source NSAP which was used for cache table look up.
    
      o  Image SYS$LOADABLE_IMAGES:NET$SESSION_CONTROL.EXE
    
         -  Correct pool leak of WQEs.
         -  Prevent PGFILPHI crash in GetLocalNodeInfo
         -  Second fix to prevent PGFILPHI crash in GetLocalNodeInfo
         -  Report delete session control port to I/O-status
            in mailbox for 3rd party disconnect.
         -  Prevent crash on session ports in the WFCNTOCMP state.
         -  Server processes are not correctly being reused.
         -  Correct possible pool corruption.
    
      o  Image SYS$LOADABLE_IMAGES:NET$TRANSPORT_NSP.EXE
    
         -  Prevent idle links from dropping when the link service ACK is
            lost.
    
      o  Image SYS$LOADABLE_IMAGES:NET$TRANSPORT_OSI.EXE
    
         - Fix chained receive used by X.25 or TCP/IP which could cause an
           application to abort.
         - Prevent error in Show DTE address with NCL.
         - Fix congestion avoidance to prevent the window from closing.
         - Fix shutdown crash in deallocate TLQs.
         - Fix race condition crash.
         - Fix memory leak with X.500 and RFC1006
         - Fix active connection count becoming negative.
         - Fix crash c_retrans_ak.
         - Fix bad throughput.
    
      o  Image SYS$LOADABLE_IMAGES:SYS$NETWORK_SERVICES.EXE
    
         -  Update ECO number in DECnet version "050704"
    
      o  New trace images included in SYS$LIBRARY for compatibility
    
         -  CTF$DNA_ANALYZE.EXE
         -  CTF$ESEVENT_ANALYZE.EXE
         -  CTF$NSPTP_ANALYZE.EXE
         -  CTF$OSITP_ANALYZE.EXE
         -  CTF$SCL_ANALYZE.EXE
         -  CTF$VOTS_ANALYZE.EXE
    
      Corrections for DECdns Client Components:
    
      o  Image SYS$LOADABLE_IMAGES:SYS$NAME_SERVICES.EXE
               SYS$SYSTEM:DNS$ADVER.EXE
               SYS$SYSTEM:DNS$CONFIGURE.EXE
               SYS$SYSTEM:DNS$CONTROL.EXE
               SYS$LIBRARY:DNS$PI.EXE
    
         -  Clerk Memory leak in convert string fullname to opaque routine.
         -  Clerk Non-paged pool memory leak
    
      Corrections for VAX P.S.I Components:
    
      o  Image SYS$LOADABLE_IMAGES:PSI$GAP.EXE
    
         -  Fix for NCB on call accept.
    
      o  Image SYS$LOADABLE_IMAGES:LES$DECNET_V30.EXE
    
         -  Include for PSI$GAP.
    
      o  Image SYS$LOADABLE_IMAGES:PSI$L3CS.EXE
    
         -  Fix X.25 counters to be correctly decremented.
         -  Fix X.25 called and calling address with an odd number of
            digits.
    
         NOTE:  The DECnet/OSI V6.1 ECO kit #1 incorrectly placed
                PSI$L3CS.EXE in SYS$COMMON:[SYSEXE].  The PSI$L3CS.EXE
                in SYS$COMMON:[SYSEXE] should be deleted.
    
      o  Image SYS$LOADABLE_IMAGES:PSI$L3CS-NMD.EXE
    
         -  Fix crash when a buffer passed to EXE$CHKPRO_INT is too small
            and attempts to write to a page with User Read Protection.
         -  Fix X.25 called and calling address with an odd number of
            digits.
    
      o  Corrections made to FCNS file in MOM$SYSTEM
    
         -  FCNS$MCNM_PRF.DAT
            FCNS$X25L2_PRF.DAT
            FCNS$X25L3_PRF.DAT
    
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in the
    DECNET-VMS database.  To view these articles, open the appropriate
    product database and perform a query using the following search
    string: 'DNVOSI_ECO04061'.
    
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services (AES)
    Service Tool.  If you are not familiar with how to request kits
    electronically, open the DIA, WIS or DSNLINK database and review the
    article entitled:
    
      [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    This ECO is installed using the POLYCENTER Software Installation
    utility.
    
       Product Kit Name: DNVOSIECO04
       PCSI Kit Name:    DEC-VAXVMS-DNVOSIECO04-V0601--4.PCSI
    
    In order for the corrections in this kit to take effect, the system must be
    rebooted.  If the system is a member of a VAXcluster, the entire cluster
    should be rebooted.
    
    
    INSTALLATION CAUTION:
    
    Due to an error in the POLYCENTER Software Installation, it is not
    possible to install DEC VAXVMS OSAK V3.0 or DEC VAXVMS FTAM V3.2 after
    installing this ECO kit.
    
    OSAK and FTAM PCSI installations require DECnet/OSI V6.1 which causes
    the installation process to remove DNVOSIECO04.  This will leave the
    system without a SYS$NETWORK_SERVICES.EXE and rebooting is not possible.
    
    The original installation order must be preserved.  This will be
    corrected in a future release.
    
       Installation Order
    
       Place each PCSI kit in a unique source directory
    
          1) DEC VAXVMS DECNET_OSI V6.1 /Source=[KITS.DECNET]
          2) DEC VAXVMS OSAK V3.0-A /Source=[KITS.OSAK]
          3) DEC VAXVMS FTAM V3.2-B /Source=[KITS.FTAM]
          4) DEC VAXVMS DNVOSIECO04 V6.1 /Source=[KITS.ECO]
    
privacy statement using this site means you accept its terms feedback to the webmaster
VMS rules VMS rocks OpenVMS rules OpenVMS rocks